Dear R
Ganeshmoorthy
Thank you for your pre-application
inquiry regarding the grade II* listed buildings situated at Nos
I can confirm that the planned works
comprising internal alterations to include the enlargement of the existing
reception area, the provision of a disabled WC and alterations to partitions in
other areas of the building will require a formal application to the Council for
listed building consent. Since the building is listed grade II*, the
Council will have to consult English Heritage on any
application.
I have the following comments to
make regarding your proposals. Please note that I am using the English
Heritage guidance on Terraced Houses in
Ground
floor
It is not acceptable to remove the
section of party wall which currently divides the two front rooms of the
property and would facilitate the expansion of the existing reception
space. This is because this wall marks the fact that the property was
originally two separate townhouses, may well have structural properties, and is
visible from the street as a return of the front elevation. It is
important that this wall remains in position as it prevents an impression of
facadism in the terrace as seen from the square.
It is also unacceptable to remove
the partition between the existing entrance corridor and the reception area as
it also defines part of the former floor plan of the townhouse and retains
something of the building’s original cellular character. It is also
visible from the street and so its presence avoids an open-plan situation which
is unacceptable at ground floor level in the front section of the building.
It is acceptable in principle to
relocate the entrance door to the front office adjacent to the reception area
(subject to detailed design), but this may not be necessary if the size of this
room is not going to be reduced (in accordance with the comments made
above).
The addition of a disabled WC is
acceptable since it is to be situated in the middle-rear section of the building
which has already been much altered. However, services should be
incorporated into the building in as discreet a manner as possible, routed away
from the front of the building, and so that where historic fabric exists it is
not harmed, wherever possible using existing service
runs.
It is acceptable to introduce a
chamfered corner to the rear office room adjacent to the entrance
hall.
First
floor
The proposed changes to the access
doors, introducing double doors, is acceptable in principle, subject to detailed
design of the new doors.
The removal of the spinal corridor
is acceptable since it is a non-original feature out-of-keeping with the
original floor plan.
The reconfiguration of the three
rear offices to create two larger offices divided by a folding partition is
acceptable, since none of the existing spaces are original. It is assumed
that the projection proposed for removal from the party wall with No 28 Fitzroy
Square is not original fabric such as a chimney breast, as the presumption would
be to retain this feature if it is of historic
value.
It is acceptable to install a second
kitchen in the middle of the floor as no historic fabric or plan form will be
affected. However, it is necessary for all servicing to be sensitively
incorporated and inserted into the building as for the ground floor WC
(above).
It is similarly acceptable to create
an internal store room in an area where no historic plan form
survives.
The removal of the plant room is
acceptable provided that the space is made good to match adjacent work and any
apertures in the external walls are sensitively filled
in.
Second
floor
As with the rear section of the
first floor, the reconfiguration of the existing office room layout, in this
case allowing for a larger central open space, is acceptable in principle.
There are reservations regarding the
positioning of a two dividing walls at the front of the floor, which ‘coincide’
with two front windows and so will be visible from the square. The
partition adjacent to the former party wall between the two former townhouses
should be realigned so as to follow its line in plan form. The second
partition, adjacent to one of the northernmost windows, should be staggered
further back from the front façade by a sufficient distance so as not to be
visible from the square.
Third
floor
The reconfiguration of partitions
forming office spaces is also acceptable at third floor
level.
As for the second floor, there are
reservations relating to a partitions adjacent to windows in the front facade
which also need to be staggered further back from the front façade by a
sufficient distance so as not to ‘coincide’ with the window and be visible from
the square.
The rear wall of the northernmost
front office should be repositioned so that it aligns with the nib of the former
spinal wall of the townhouse. The existing arrangement with a small gap
between the two walls creates an awkward gap.
Basement
The conversion and opening up of the
existing rear store room and adjacent office into one larger office space is
acceptable since it affects an area of secondary importance in the listed
building which would appear to be a later
extension.
I trust this information is of
assistance. If you have any questions on any of the above points or
relating to a future listed building consent application, please do not hesitate
to contact me on my direct line number or by
e-mail.
Please note that
this is an officer’s opinion and does not prejudice any future decision made by
the Council with regards to this matter.
Principal Planner (Conservation and Heritage)
Regeneration and
Planning
Culture and Environment
Telephone: 020
7974
2669
Fax: 020
7974
1680
Web: camden.gov.uk
6th Floor.
Town
Hall Extension (Culture and Environment)
Argyle Street
Please consider the environment before printing this
email.